  一、加油站油气回收检测概述

  1、 Overview of Oil and Gas Recovery Testing at Gas Stations

  01检测方法液阻检测方法。以规定的氮气流量向油气回收管线内充入氮气,模拟油气通过油气回收管线。用压力表或同等装置检测气体通过管线的液体阻力,了解管线内因各种原因对气体产生阻力的程度,用来判断是否影响油气回收。密闭性检测方法。用氮气对油气回收系统加压至500Pa,允许系统压力衰减。检测5min后的剩余压力值与表

  01 Detection method: Liquid resistance detection method. Inject nitrogen into the oil and gas recovery pipeline at a specified nitrogen flow rate to simulate the passage of oil and gas through the pipeline. Use a pressure gauge or equivalent device to detect the liquid resistance of gas passing through the pipeline, understand the degree of resistance caused by various reasons in the pipeline to determine whether it affects oil and gas recovery. Sealing testing method. Pressurize the oil and gas recovery system with nitrogen to 500Pa, allowing the system pressure to decay. Detect the remaining pressure value after 5 minutes and compare it with the table

  2规定的最小剩余压力限值进行比较,如果低于限值,表明系统泄漏程度超出允许范围。气液比检测方法。在加油枪的喷管处安装一个密合的适配器。该适配器与气体流量计连接,气流先通过气体流量计,然后进入加油枪喷管上的油气收集孔。所计量的气体体积与加油机同时计量的汽油体积的比值称为气液比。

  Compare the minimum residual pressure limit specified in 2, and if it is lower than the limit, it indicates that the degree of system leakage exceeds the allowable range. Gas liquid ratio detection method. Install a tight fitting adapter at the nozzle of the fuel gun. This adapter is connected to a gas flow meter, and the airflow first passes through the gas flow meter before entering the oil and gas collection hole on the nozzle of the fuel gun. The ratio of the volume of gas measured to the volume of gasoline measured simultaneously by the fuel dispenser is called the gas-liquid ratio.1694b8142463c9dd216c40b67fe63ac

  01通过气液比的检测,可以了解油气回收系统的回收效果。

  By detecting the gas-liquid ratio, the recovery efficiency of the oil and gas recovery system can be understood.

  02计量器具控制计量器具控制包括首次检测和后续检测。

  02 Measuring Instrument Control Measuring instrument control includes initial testing and subsequent testing.

  03检测条件环境温度(0-35)℃,常压。

  03 Testing conditions: Environmental temperature (0-35) ℃, atmospheric pressure.

  04检测用设备氮气罐、压力表、浮子流量计、适配器、加压软管、快接接头、气体流量计、检测用油桶。

  04 Testing equipment includes nitrogen tanks, pressure gauges, float flow meters, adapters, pressure hoses, quick couplings, gas flow meters, and oil drums for testing.

  05检测项目1.液阻检测2.密闭性检测3.气液比检测二、加油站油气回收检测流程1检测前的准备2通知被测单位提前设备自检现场检测前先和被测单位取得联系,要求油气回收装置的施工、安装单位人员先期到达被测单位进行设备自检,要求管道无泄漏,对所有用于油气回收装置的各个零部件的工作状态进行调试,确定其工作正常、稳定。

  05 Testing items: 1. Liquid resistance testing 2. Airtightness testing 3. Gas liquid ratio testing 2. Gas station oil and gas recovery testing process 1. Preparation before testing 2. Notify the tested unit to conduct equipment self inspection in advance. Contact the tested unit before on-site testing, and require personnel from the construction and installation units of the oil and gas recovery device to arrive at the tested unit for equipment self inspection in advance. Ensure that the pipeline is leak free, and debug the working status of all components used for the oil and gas recovery device to ensure that they are working normally and stably.

  3通知被测单位做好检测准备检测工作具体时间需提前通知被测单位,要求做好满罐存油准备以有利于检测,在检测之前24小时内不允许进行气液比检测,在检测前3小时内和在现场检测过程中,不得有大批量油品进出储油罐,在检测前30分钟停止加油作业。用安全围栏圈定现场检测区域、油罐并操作区域,提出安全警示,现场准备消防设施(干粉灭火器、石棉毯等),非现场操作人员不得进入相关区域。现场工作人员需按照相关安全要求更换防静电工作服、关闭所有通讯设备、车辆熄火、不许携带火源等,严格遵守被检单位的其他要求。

  3. Notify the tested unit to prepare for testing. The specific time for testing work needs to be notified in advance, and it is required to prepare for full tank storage to facilitate testing. Gas liquid ratio testing is not allowed within 24 hours before testing. Within 3 hours before testing and during on-site testing, there should be no large quantities of oil entering or leaving the storage tank. Refueling operations should be stopped 30 minutes before testing. Use safety fences to delineate the on-site inspection area, oil tank and operation area, issue safety warnings, prepare fire-fighting facilities on site (dry powder fire extinguishers, asbestos blankets, etc.), and non on-site operators are not allowed to enter the relevant areas. On site staff are required to replace anti-static work clothes, turn off all communication equipment, turn off vehicles, and prohibit carrying fire sources in accordance with relevant safety requirements, and strictly comply with other requirements of the inspected unit.

  本文由油气回收设备   友情奉献.更多有关的知识请点击  http://www.kosman.com.cn/   真诚的态度.为您提供为全面的服务.更多有关的知识我们将会陆续向大家奉献.敬请期待.

  This article is a friendly contribution from oil and gas recovery equipment For more related knowledge, please click http://www.kosman.com.cn/ Sincere attitude To provide you with comprehensive services We will gradually contribute more relevant knowledge to everyone Coming soon.

    联系我们
    17515661888

    地址:山东省菏泽市成武县经济开发区机电产业园钢架结构单层5号

    【微信二维码】
留言咨询

Adopting different technology and process control schemes

姓名:
电话:
科仕曼环境科技有限公司 鲁ICP备2025167239号-1 鲁公网安备 337172302372103号